• Trane Manuals
  • Air Conditioner
  • Voyager Commercial
  • Installation, operation and maintenance manual

Trane Voyager Commercial Installation, Operation And Maintenance Manual

  • Installation & operation manual (152 pages)
  • Manual (93 pages)
  • page of 156 Go / 156

Table of Contents

  • Troubleshooting

Model Number Description

  • 60 Hz Description
  • 50 Hz Description

General Information

  • About the Unit
  • Exterior Inspection

Unit Dimensions and Weights

  • Recommended Clearances
  • Horizontal Ductwork
  • Unit Dimensions
  • Unit Rigging and Placement

Pre-Installation

  • Downflow/Upflow Models
  • Field Installed Control Wiring
  • Gas Heat Requirements

Installation General Requirements

  • Condensate Drain Connection
  • Condensate Overflow Switch
  • O/A Sensor & Tubing Installation
  • Units with Statitrac

Installation Electrical

  • Disconnect Switch External Handle
  • (Factory Mounted Option)
  • Main Power Wiring
  • Through-The-Base Electrical
  • Electrical Service Sizing Data
  • Electrical Wire Sizing and Protection
  • Calculation #1 - TC*, YC* - 27.5 to
  • Calculation #2 - TE* - 27.5 to 50 Ton
  • Disconnect Switch Sizing (DSS)
  • Low Voltage Wiring
  • Control Power Transformer
  • Field Installed AC Control Wiring
  • Field Installed DC Control Wiring
  • Constant Volume and Single Zone VAV Control Options
  • Variable Air Volume (Non-SZ VAV)
  • Control Options
  • VAV Controls Available from the Factory for Field Installation
  • Constant Volume or VAV
  • Installation
  • Space Temperature Averaging

Installation Piping

  • General Requirements
  • Connecting the Gas Supply Line to the Furnace Gas Train

Furnace Gas Train

  • ECA/RTEM - Economizer Actuator
  • Reliatel Economizer Module
  • EBA - Exhaust Blade Actuator
  • RTAM - Reliatel Air Handler Module
  • (Standard with Traditional VAV)
  • Reliatel Ventilation Module
  • Reliatel Dehumidification Module
  • Conventional Thermostat Connections
  • TCI - Trane Communication Interface
  • LCI - Lontalk® Communication
  • Interface (Optional)
  • BCI - Bacnet® Communication
  • WCI - Trane Air-Fi™ Wireless Comm Interface (Optional)
  • Microelectronic Control
  • Modulating Power Exhaust
  • Mechanical Cooling Without an Economizer (CV and SZ VAV)
  • Zone Temperature - Occupied Cooling (CV and SZVAV)
  • Zone Temperature - Occupied Heating (CV and SZVAV)
  • Supply Fan (CV and SZ VAV)
  • Supply Air Tempering

Variable Air Volume Applications

  • Supply Fan Output Control
  • Minimum Supply Fan Output
  • Supply Fan Mode Operation
  • Setpoint Arbitration
  • Units Configured with the Outside Air Measurement (Traq) Option
  • Calibration
  • Ventilation Control
  • Space Pressure Control
  • Traq Overrides and Special
  • Considerations
  • Supply Air Temperature Control - Heating and Cooling
  • Supply Air Temperature Control - Occupied Cooling and Heating
  • Supply Air Temperature Control with
  • An Economizer
  • VHR Relay Output
  • Zone Temperature Control Without a
  • Night Setback Panel or ICS
  • Unoccupied Cooling
  • Unoccupied Heating

Applications (Single Zone or

  • Supply Duct Static Pressure
  • Supply Air Temperature Reset
  • VAV Supply Air Tempering

Constant Volume or Variable Air Volume

Traditional).

  • Cooling (CV or SZ VAV Only)
  • Gas Heat Control
  • Electric Heat Control
  • Clogged Filter Option
  • Ventilation Override
  • Emergency Stop
  • Phase Monitor
  • Low Pressure Control
  • High Pressure Cutout and Temperature Discharge Limit
  • Power Exhaust Control
  • Lead/Lag Control
  • Coil Frost Protection
  • Modulating Hot Gas Reheat Frost
  • Switch (Optional)
  • VFD Programming Parameters

Preparing the Unit for Operation

  • Electrical Phasing
  • Voltage Supply and Voltage

Starting the Unit

  • Service Test Switch Location
  • Verifying Proper Fan Rotation
  • Verifying Proper Air Flow (CFM) - CV
  • Or Vfd's
  • Exhaust Fan Operation

Economizer Damper Adjustment

  • Economizer (O/A) Dampers
  • Models with Ultra-Low Leak
  • Economizers
  • Manual Outside Air Damper

Starting the Compressor

  • Starting 27.5 to 35 Ton Standard
  • Efficiency Units
  • Starting 40 to 50 Ton Standard Efficiency VAV Units
  • Starting 27.5-50 Tons High Efficiency
  • Units and 40-50 Tons Standard
  • Line Weights
  • Compressor Oil
  • Charging by Subcooling
  • Measuring Subcooling
  • Gas Heat Units
  • Electric Heat Units
  • For Constant Volume Units
  • For Variable Air Volume Units
  • For Single Zone Variable Air Volume

Sequence of Operation

  • Mechanical Cooling Sequence of
  • Units Without an Economizer
  • Economizer Operation Based on Dry
  • Economizer Operation Based on Reference Enthalpy
  • Economizer Operation Based on Comparative Enthalpy
  • Economizers with Traq
  • Modulating Hot Gas Reheat Sequence of
  • Sensible Cooling or Heating Control
  • Overrides Hot Gas Reheat
  • Constant Volume (CV) Unit Fan
  • Variable Air Volume (VAV) Unit Fan
  • Ignition Control Module
  • High Temperature Limit Operation
  • And Location
  • Constant Volume (CV)
  • Variable Air Volume (VAV)

Zone VAV) Sequence of Operation

  • Occupied Cooling Operation
  • Economizer Cooling
  • Compressor Cooling
  • Occupied Heating Operation
  • Staged Heating Operation
  • Modulating Heat Operation with
  • SZVAV Heating
  • Unoccupied Cooling and Heating
  • Modulating Hot Gas Reheat

Operation (Reliatel Control)

  • Low Pressure Control (LPC) Sequence of Operation (Reliatel Control)
  • High Pressure Control and Temperature Discharge Limit (Reliatel Control)

Discharge Limit (Reliatel Control)

Maintenance.

  • Fan Belt Adjustment
  • Cooling Season
  • Heating Season
  • Refrigerant Coils
  • Microchannel Condenser Coil Repair
  • And Replacement
  • Final Process
  • Fall Restraint
  • Refrigerant Evacuation and Charging
  • Charge Storage
  • Precision Suction Restrictor

Diagnostics

  • System Status / Diagnostics Checkout
  • Diagnostics (VAV Only)
  • Resetting Cooling and Ignition
  • Zone Temperature Sensor (ZSM)
  • Service Indicator

Economizer Actuator (ECA/RTEM) Test

  • Economizer Fault Detection and Diagnostics
  • Verify Economizer Status by
  • Economizer Actuator
  • Test 1: Testing the Variable Frequency Drive (VFD) Output
  • Test 2: Testing the Static Pressure Transducer (SPT) Input
  • Test 3: Testing the VAV Setpoint
  • Potentiometers
  • Test 4: Testing the VFD
  • Test 2: Testing the VFD
  • Compressor-Blink Codes
  • TR-200 VFD Programming

Unit Wiring Diagram Numbers

And largerand related, warranty and liability clause.

  • Commercial Equipment - 20 Tons
  • Accessories

Advertisement

Quick Links

  • 1 Model Number Description
  • 2 60 Hz Description
  • 3 Low Voltage Wiring
  • 4 Unit Wiring Diagram Numbers
  • Download this manual

Related Manuals for Trane Voyager Commercial

Air Conditioner Trane Voyager Manual

Summary of Contents for Trane Voyager Commercial

  • Page 1 Installation, Operation, and Maintenance Voyager™ ™ Commercial Packaged Rooftop Air Conditioners with ReliaTel™ Controls and eStage™ 27.5 to 50 Tons - 60 Hz 22.9 to 41.7 Tons (81-148 kW) - 50 Hz “B” and later design sequence 6 6 0 0 H H z z / / 3 3 p p h h a a s s e e : TC*, TE*, YC*330B, 360B, 420B, 480B, 600B (60 Hz/3 phase) 5 5 0 0 H H z z / / 3 3 p p h h a a s s e e : TC*, TE*,...
  • Page 2 A A L L W W A A Y Y S S r r e e f f e e r r t t o o a a p p p p r r o o p p r r i i a a t t e e S S a a f f e e t t y y D D a a t t a a impact to the environment. Trane advocates the...
  • Page 3 . . This document and the information in it are the property of Trane, and may not be used or reproduced • •...

Page 4: Table Of Contents

  • Page 5 Interface (Optional)....44 Night Setback Panel or ICS - WCI - Trane Air-Fi™ Wireless Comm Unoccupied Cooling....57 Interface (Optional).
  • Page 6 T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Power Exhaust Control Final Unit Checkout ..... 106 (Tracking) .
  • Page 7 T T a a b b l l e e o o f f C C o o n n t t e e n n t t s s Modulating Heat Operation with System Status / Diagnostics Checkout SZVAV Heating ..... 113 Procedure (DC Voltmeter Unoccupied Cooling and Heating Required) .

Page 8: Model Number Description

  • Page 9 E = Field-Powered 15A GFI Convenience Outlet Digit 33 — Human Interface Digit 22 5 = Touchscreen Human Interface, 5inch F = Trane Communication Interface (TCI) Model Number Notes Digit 23 Notes: G = Ventilation Override All voltages are across the line starting only.

Page 10: 50 Hz Description

  • Page 11 Digit 22 The service digit for each model number contains 33 digits; all 33 digits must be F = Trane Communication Interface (TCI) referenced. Ventilation override exhaust mode is not Digit 23 available for the exhaust fan with fresh air tracking power exhaust.

Page 12: General Information

Page 13: unit dimensions and weights, page 14: unit dimensions.

  • Page 15 U U n n i i t t D D i i m m e e n n s s i i o o n n s s a a n n d d W W e e i i g g h h t t s s Figure 3.
  • Page 16 U U n n i i t t D D i i m m e e n n s s i i o o n n s s a a n n d d W W e e i i g g h h t t s s Figure 5.
  • Page 17 U U n n i i t t D D i i m m e e n n s s i i o o n n s s a a n n d d W W e e i i g g h h t t s s Figure 7.
  • Page 18 U U n n i i t t D D i i m m e e n n s s i i o o n n s s a a n n d d W W e e i i g g h h t t s s Figure 9.

Page 19: Unit Rigging And Placement

  • Page 20 2189.5 Note: Weights shown represent approximate operating weights and have a ±10% accuracy. To calculate weight for a specific unit configuration, utilize TOPSS™ or contact the local Trane® sales representative. ACTUAL WEIGHTS ARE STAMPED ON THE UNIT NAMEPLATE. Table 5. Point loading average weight— lbs./kg...
  • Page 21 U U n n i i t t D D i i m m e e n n s s i i o o n n s s a a n n d d W W e e i i g g h h t t s s Table 6.

Page 22: Pre-Installation

Page 23: installation general requirements, page 24: units with statitrac.

  • Page 25 I I n n s s t t a a l l l l a a t t i i o o n n G G e e n n e e r r a a l l R R e e q q u u i i r r e e m m e e n n t t s s Figure 18.

Page 26: Installation Electrical

  • Page 27 I I n n s s t t a a l l l l a a t t i i o o n n E E l l e e c c t t r r i i c c a a l l •...

Page 28: Through-The-Base Electrical

  • Page 29 I I n n s s t t a a l l l l a a t t i i o o n n E E l l e e c c t t r r i i c c a a l l Table 8.
  • Page 30 I I n n s s t t a a l l l l a a t t i i o o n n E E l l e e c c t t r r i i c c a a l l Table 11.

Page 31: Electrical Wire Sizing And Protection

Page 32: disconnect switch sizing (dss), page 33: field installed dc control wiring.

  • Page 34 I I n n s s t t a a l l l l a a t t i i o o n n E E l l e e c c t t r r i i c c a a l l •...
  • Page 35 I I n n s s t t a a l l l l a a t t i i o o n n E E l l e e c c t t r r i i c c a a l l Figure 22.

Page 36: Remote Panels And Sensors

Page 37: vav controls available from the factory for field installation.

  • Page 38 I I n n s s t t a a l l l l a a t t i i o o n n E E l l e e c c t t r r i i c c a a l l Figure 30.

Page 39: Space Temperature Averaging

Page 40: installation piping.

  • Page 41 I I n n s s t t a a l l l l a a t t i i o o n n P P i i p p i i n n g g Table 19. Specific gravity multiplier Table 19.

Page 42: Startup

Page 43: reliatel ventilation module, page 44: reliatel dehumidification module, page 45: microelectronic control, page 46: modulating power exhaust, page 47: zone temperature - occupied cooling (cv and szvav), page 48: variable air volume applications, page 49: supply fan mode operation, page 50: units configured with the outside air measurement (traq) option, page 51: calibration.

  • Page 52 S S t t a a r r t t u u p p Table 29. Design minimum OA flow setpoint Table 29. Design minimum OA flow setpoint (continued) (continued) Design Min OA Flow DCV Min OA Flow Voltage Design Min OA Flow DCV Min OA Flow Voltage Setpoint (R130)

Page 53: Ventilation Control

  • Page 54 S S t t a a r r t t u u p p Figure 41. SZVAV DCV with OA CFM Figure 42. Minimum outside air CFM setpoint compensation Design @ Minimum Fan Speed (RTVM R130) Posi on Setpoints Corresponds to Design CO2 (DCV UL) Setpoint Design @ Middle Fan Speed (RTVM R136)

Page 55: Space Pressure Control

Page 56: traq overrides and special, page 57: variable air volume applications, page 58: supply duct static pressure, page 59: cooling (cv or sz vav only), page 60: electric heat control, page 61: control, page 62: power exhaust control, page 63: switch (optional).

  • Page 64 S S t t a a r r t t u u p p Table 38. Condenser fan/compressor sequence - std efficiency (continued) Compressor Staging Sequence Condenser Fan Output O/A Temp. (°F) Unit Size (Ton) Step 1 Step2 Step 3 Output A Output B Fans “Off”...
  • Page 65 S S t t a a r r t t u u p p Table 39. Condenser fan/compressor sequence - high efficiency 27.5-35 Ton High Efficiency Compressor Stage 1 Compressor Stage 2 Ambient Ambient # Cond # Cond Fan #1 Fan #2 Fan #3 Fan #1...

Page 66: Preparing The Unit For Operation

Page 67: voltage supply and voltage, page 68: service test switch location.

  • Page 69 S S t t a a r r t t u u p p Table 41. Test mode states for traditional VAV units with modulating hot gas reheat and staged heat COOL TEST COMP PUMP- COMP COMP HEAT HEAT VAL- HEAT STEP MODE...
  • Page 70 S S t t a a r r t t u u p p Table 42. Test mode states for CV units with modulating hot gas reheat and staged heat COOL TEST COMP COMP COMP HEAT HEAT VAL- HEAT STEP MODE ECON PUMPOUT...
  • Page 71 S S t t a a r r t t u u p p Table 43. Test mode states for SZ VAV units with modulating hot gas reheat and staged heat COOL TEST COMP PUMP- COMP COMP HEAT HEAT VAL- HEAT STEP MODE...
  • Page 72 S S t t a a r r t t u u p p Table 44. Test mode states for traditional VAV units with modulating hot gas reheat and modulating heat COOL TEST COMP HEAT PUMP- COMP COMP VAL- HEAT STEP MODE COMMAND...
  • Page 73 S S t t a a r r t t u u p p Table 45. Test mode states for CV units with modulating hot gas reheat and modulating heat TEST COMP COMP COMP HEAT PUMP- COOL HEAT STEP MODE ECON OUTPUT VALVE...

Page 74: Verifying Proper Fan Rotation

Page 75: verifying proper air flow (cfm) - cv.

  • Page 76 S S t t a a r r t t u u p p Figure 51. Supply fan performance curves 40 and 50 ton — 60Hz Figure 52. Supply fan performance — 22.9-29.2 tons — 50Hz Supply Fan Performance (996) (872) (747) (623)
  • Page 77 S S t t a a r r t t u u p p Figure 53. Supply fan performance — 33.3 and 41.7 ton (IP) — 50Hz (1245) (996) (747) (498) (249) (0.0) 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000...
  • Page 78 S S t t a a r r t t u u p p Table 47. TC*/YC*300–600 MBH economizer (R/A) Table 47. TC*/YC*300–600 MBH economizer (R/A) damper pressure drop – 60Hz damper pressure drop – 60Hz (continued) Unit Capacity Airflow (CFM) Pressure Drop (iwc) Unit Capacity Airflow (CFM) Pressure Drop (iwc) 8000...
  • Page 79 S S t t a a r r t t u u p p Table 48. Supply air fan drive selections — 60 Hz 7.5 HP 10 HP 15 HP 20 HP Nominal Tons Drive No. Drive No. Drive No. Drive No.
  • Page 80 S S t t a a r r t t u u p p Table 49. Component static pressure drops (in. W.G.) — 60Hz Heating System Filters Standard High MERV Efficiency Efficiency Throw- Hot Gas MERV 8 High Eff Gas Heat Electric Heat 14 High Nom.
  • Page 81 S S t t a a r r t t u u p p Table 50. Component static pressure drops in. W.G (I-P) — 50Hz (continued) Heating System Filters Standard High MERV Efficiency Efficiency Throw- Hot Gas MERV 8 High Eff Gas Heat Electric Heat 14 High...
  • Page 82 S S t t a a r r t t u u p p Table 51. Component static pressure drops Pa (SI) — 50 Hz (continued) Heating System Standard Filters Nom. Std Efficiency ID Throw- MERV 14 L/s Std Econo- MERV 8 High Eff Gas Heat Electric Heat...

Page 83: Exhaust Fan Operation

Page 84: economizer damper adjustment.

  • Page 85 S S t t a a r r t t u u p p duct static pressures and over pressurization of the Table 57. 27.5 - 35 Ton downflow economizer (O/A) damper static pressure setup (continued) space when the unit is operating in the “economizer” mode.

Page 86: Models With Ultra-Low Leak

  • Page 87 S S t t a a r r t t u u p p switch is set back to its original default position - Y Figure 62. Actuator auto-scaling feature details = 0 - same direction as spring return. (See Figure 62, p.

Page 88: Manual Outside Air Damper

Page 89: starting the compressor, page 90: starting 40 to 50 ton standard efficiency vav units, page 91: compressor oil.

  • Page 92 S S t t a a r r t t u u p p motor burnout. If the oil is black and contains metal Refer to the refrigeration system in the maintenance flakes, a mechanical failure has occurred. This section for details on testing and replacing oil. symptom is often accompanied by a high compressor amperage draw.
  • Page 93 S S t t a a r r t t u u p p Figure 74. 35 Ton operating pressure — standard efficiency (60 Hz) Figure 75. 40 Ton dual circuit operating pressure, Cir #1 — standard efficiency VAV (60 Hz) RT-SVX34R-EN...
  • Page 94 S S t t a a r r t t u u p p Figure 76. 40 Ton dual circuit operating pressure Cir #2 — standard efficiency VAV (60 Hz) Figure 77. 40 Ton operating pressure — standard efficiency CV (60 Hz) 120F OD Ambient 115F OD Ambient 105F OD Ambient...
  • Page 95 S S t t a a r r t t u u p p Figure 78. 50 Ton dual circuit operating pressure Cir #1 — standard efficiency VAV (60 Hz) Figure 79. 50 Ton dual circuit operating pressure Cir #2 — standard efficiency VAV (60 Hz) RT-SVX34R-EN...
  • Page 96 S S t t a a r r t t u u p p Figure 80. 27.5 Ton operating pressure — high efficiency (60 Hz) Figure 81. 30 Ton operating pressure — high efficiency (60 Hz) RT-SVX34R-EN...
  • Page 97 S S t t a a r r t t u u p p Figure 82. 35 Ton operating pressure — high efficiency (60 Hz) Figure 83. 40 Ton operating pressure — high efficiency (60 Hz) RT-SVX34R-EN...
  • Page 98 S S t t a a r r t t u u p p Figure 84. 50 Ton operating pressure — high efficiency and standard efficiency CV (60 Hz) Figure 85. 22.9 Ton operating pressure — standard efficiency (50 Hz) RT-SVX34R-EN...
  • Page 99 S S t t a a r r t t u u p p Figure 86. 25.4 Ton operating pressure — standard efficiency (50 Hz) Figure 87. 29.2 Ton operating pressures — standard efficiency (50 Hz) RT-SVX34R-EN...
  • Page 100 S S t t a a r r t t u u p p Figure 88. 33.3 Ton operating pressure — standard efficiency CV (50 Hz) 120F OD Ambient 115F OD Ambient 105F OD Ambient 95F OD Ambient 85F OD Ambient 75F OD Ambient 65F OD Ambient 55F OD Ambient...
  • Page 101 S S t t a a r r t t u u p p Figure 90. 33.3 Ton dual circuit operating pressure, circuit #2 — standard efficiency VAV (50 Hz) Figure 91. 41.7 Ton dual circuit operating pressure, circuit #1 — standard efficiency VAV (50 Hz) RT-SVX34R-EN...
  • Page 102 S S t t a a r r t t u u p p Figure 92. 41.7 Ton dual circuit operating pressure, circuit #2 — standard efficiency VAV (50 Hz) Figure 93. 22.9 Ton operating pressure — high efficiency (50 Hz) RT-SVX34R-EN...
  • Page 103 S S t t a a r r t t u u p p Figure 94. 25.4 Ton operating pressure — high efficiency (50 Hz) Figure 95. 29.2 Ton operating pressure — high efficiency (50 Hz) RT-SVX34R-EN...
  • Page 104 S S t t a a r r t t u u p p Figure 96. 33.3 Ton operating pressure — high efficiency (50 Hz) Figure 97. 41.7 Ton operating pressure — high efficiency and standard efficiency CV (50 Hz) RT-SVX34R-EN...

Page 105: Noises

Page 106: electric heat units, page 107: for single zone variable air volume, page 108: sequence of operation, page 109: economizer operation based on reference enthalpy, page 110: modulating hot gas reheat sequence of, page 111: constant volume (cv) unit fan, page 112: variable air volume (vav), page 113: occupied heating operation, page 114: modulating hot gas reheat, page 115: low pressure control (lpc) sequence of operation (reliatel control), page 116: maintenance.

  • Page 117 M M a a i i n n t t e e n n a a n n c c e e Table 66. Belt tension measurements and deflection forces Deflection Force (Lbs.) Steel Cable 358 Gripnotch Belts Super Gripbelts Gripnotch Gripbelts 358 Gripbelts...

Page 118: Monthly Maintenance

Page 119: cooling season, page 120: coil cleaning, page 121: refrigerant coils.

  • Page 122 M M a a i i n n t t e e n n a a n n c c e e RT-SVX34R-EN...

Page 123: Fall Restraint

Page 124: charge storage, page 125: vfd programming parameters.

  • Page 126 M M a a i i n n t t e e n n a a n n c c e e g. Ensure parameter 14-22 Operation Mode has 4. Follow the start-up procedures for supply fan in the reverted back to “Normal Operation”. “Variable Air Volume System”...
  • Page 127 M M a a i i n n t t e e n n a a n n c c e e Table 72. Supply fan VFD programming parameters Menu Name Unit Language English US 0-01 Regional Settings 0-03 North America Set to applicable unit power supply 200-240V/60Hz for 200 &...
  • Page 128 M M a a i i n n t t e e n n a a n n c c e e Table 72. Supply fan VFD programming parameters (continued) Menu Name Unit Terminal 53 Low Ref./Feedb. 6-14 Value Analog In/Out Terminal 53 High Ref./Feedb.

Page 129: Diagnostics

  • Page 130 D D i i a a g g n n o o s s t t i i c c s s depending on the type of meter used. Some meters N N o o t t e e : : Since CV units may use a conventional may only pulse between 20 and 30 volts DC.

Page 131: Diagnostics (Vav Only)

  • Page 132 D D i i a a g g n n o o s s t t i i c c s s Smoke Detector Switch Table 74. Resistance values (continued) The LED will flash anytime that the N.O. Smoke Zone or Set Detector input is closed and will be reset anytime that Point Nominal ZTEMP...
  • Page 133 D D i i a a g g n n o o s s t t i i c c s s directions, LED is open. If low in both directions, Table 76. Constant volume and single zone VAV default operations LED is shorted.

Page 134: Procedures

Page 135: reliatel air module (rtam) tests, page 136: reliatel air module (rtom) tests, page 137: troubleshooting.

  • Page 138 D D i i a a g g n n o o s s t t i i c c s s Table 79. Troubleshooting (continued) SYMPTOM PROBABLE CAUSE RECOMMENDED ACTION 1. Perform OAS Resistance/Temperature check. 1. OAS has failed. Replace if necessary.
  • Page 139 D D i i a a g g n n o o s s t t i i c c s s Table 79. Troubleshooting (continued) SYMPTOM PROBABLE CAUSE RECOMMENDED ACTION M. Low Heat Capacity Intermittent Heat. (YC’s only) CFM runs in LO or HI Check CFM, test LO and HI speed windings.
  • Page 140 D D i i a a g g n n o o s s t t i i c c s s Table 79. Troubleshooting (continued) SYMPTOM PROBABLE CAUSE RECOMMENDED ACTION 1. Check the return air sensor (RAS) at connector P10 by disconnecting P10 from RAT on the ECA.
  • Page 141 D D i i a a g g n n o o s s t t i i c c s s Table 80. Component failure mode (continued) COMPONENT FAILURE RESPONSE NORMAL RANGE DIAGNOSTIC If a sensor is used at RTRM J6-1 and J6-2, Cannot control at ZSM, unit Cool Failure Output at RTRM J6-8 to J6-6 HSP and CSP for CV or SZ VAV...

Page 142: Tr-200 Vfd Programming

  • Page 143 D D i i a a g g n n o o s s t t i i c c s s W W A A R R N N I I N N G G Use [▲] and [▼] buttons to adjust the digit Press [Cancel] button to disregard change, or H H a a z z a a r r d d o o u u s s V V o o l l t t a a g g e e w w / / C C a a p p a a c c i i t t o o r r s s ! ! press [OK] to accept change and enter the new...

Page 144: Unit Wiring Diagram Numbers

  • Page 145 U U n n i i t t W W i i r r i i n n g g D D i i a a g g r r a a m m N N u u m m b b e e r r s s Table 82.
  • Page 146 U U n n i i t t W W i i r r i i n n g g D D i i a a g g r r a a m m N N u u m m b b e e r r s s Table 82.
  • Page 147 U U n n i i t t W W i i r r i i n n g g D D i i a a g g r r a a m m N N u u m m b b e e r r s s Table 83.
  • Page 148 U U n n i i t t W W i i r r i i n n g g D D i i a a g g r r a a m m N N u u m m b b e e r r s s Table 83.
  • Page 149 U U n n i i t t W W i i r r i i n n g g D D i i a a g g r r a a m m N N u u m m b b e e r r s s Table 84.
  • Page 150 U U n n i i t t W W i i r r i i n n g g D D i i a a g g r r a a m m N N u u m m b b e e r r s s Table 84.
  • Page 151 U U n n i i t t W W i i r r i i n n g g D D i i a a g g r r a a m m N N u u m m b b e e r r s s Table 85.

Page 152: Warranty And Liability Clause

  • Page 153 N N o o t t e e s s RT-SVX34R-EN...
  • Page 154 N N o o t t e e s s RT-SVX34R-EN...
  • Page 155 N N o o t t e e s s RT-SVX34R-EN...
  • Page 156 For more information, please visit trane.com or tranetechnologies.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

Rename the bookmark

Delete bookmark, delete from my manuals, upload manual.

  • Mark Forums Read
  • Who's Online
  • Thanks / Like Statistics
  • Hottest Threads / Posts
  • Contracting Business
  • Advanced Search

Home

  • The ARPA Zone/Open Membership Discussion Forums
  • Tech to Tech Chat - Commercial

Trane Voyager ignition control module

  • Cookie Consent We use cookies to improve your website experience. To learn about our use of cookies and how you can manage your cookie settings, please see our Cookie Policy . By continuing to use the website, you consent to our use of cookies.
  • Gain access to our free AOP (Ask a Professional) Section to get real answers for your questions. All this and much more is available to you absolutely free when you register ; for an account, so join our community today today! We suggest not registering using an AT&T, BellSouth, AOL or Yahoo email address. If you have any problems with the registration process or your account login, please contact support .

Thread: Trane Voyager ignition control module

Thread tools.

  • Show Printable Version
  • View Profile
  • View Forum Posts
  • View Forum Threads

chill67 is offline

md# YCD150D4LBBB ICM board #X13650882-01 Anyone have any detailed troubleshooting info. on this control? IO&M doesn't say much about it. Thanks!!

just_opinion is offline

Originally Posted by chill67 md# YCD150D4LBBB ICM board #X13650882-01 Anyone have any detailed troubleshooting info. on this control? IO&M doesn't say much about it. Thanks!! All diagnoses and test are on the frnot of that small panel. That's it buddy. This POS does not tell you what failed. It just says "cool fail" or "heat fail" by measuring voltage between terminal 6,7,8. Even those blooming idiots from trane could not tell what part caused the failure. They say "cycle the power and hope for the best"

Gleng is offline

Will check Trane voyager manual and let you know if i find anything that helps!!!
  • Visit Homepage

dandyme is offline

here you go
Last edited by dandyme; 01-07-2011 at 07:16 PM .
It`s better to be silent and thought the fool; than speak and remove all doubt.
Thanks for the info!!!

teknics is offline

I guess the info was removed? Having a hard time finding this paperwork or PDF!
nothing in that profile indicates you are a service tech, more than likely, I removed it after giving them enough time to see it generally will not put tech lit in open forum, never know who's lurking out there

carmon's Avatar

good luck ..... worst ignition system in the trade by far.....
it was working.... played with it.... now its broke.... whats the going hourly rate for HVAC repair

jpsmith1cm is offline

Moved to tech to tech commercial

rricci is offline

Do you still have the info on the voyager,buddy?

Talz is offline

I too would love some info on this board. Apparently it offers several configurations for wiring and operation, but info is very scarce.

timebuilder's Avatar

Pro members should seek Pro info in the Pro forum.
[Avatar photo from a Florida training accident. Everyone walked away.] 2 Tim 3:16-17 RSES CMS, HVAC Electrical Specialist Member, IAEI AOP Forum Rules: Rules For Equipment Owners. Equipment Owners Find a Contractor HERE! Rules For Professional Members * To get your (*), Click Here. How to become a Professional Member.
  • Private Messages
  • Subscriptions
  • Search Forums
  • Forums Home
  • The #1 question asked by NEW MEMBERS. Please read this...
  • Questions About Becoming A Professional Member? Step Inside...
  • SITE Software Issues? Post Them Here
  • RULES for AOP - Owner Assistance and Contractors
  • AOP Residential HVAC (Beenthere Zone)
  • AOP Commercial HVAC
  • General Discussion
  • Job Wanted/Needed Discussion
  • Industry and Forum News
  • Webinars and Virtual Events
  • Tech to Tech Chat - Residential
  • Refrigeration & Ice Making
  • Members Inventions **NEW
  • Test & Balancing Forum NEW
  • Control Sales Forum
  • Professional Controls Forum
  • Control Jobs Forum
  • Chillers Open Forum
  • Energy Efficiency and Building Performance Discussion NEW
  • Commercial Food Service Equipment
  • Residential Geo Thermal / Water Source
  • Commercial Geo Thermal / Water Source
  • Indoor Air Quality
  • Tools & Test Equipment
  • Food and Grill Forum
  • "Wall of Pride" - Pictures
  • "Wall of Shame" - Pictures
  • How To Become a Pro and Rules For Pro Members
  • Pro's Forum: General Discussion
  • Charlie's Corner (Icemeister)
  • HVAC Basics **NEW
  • Pro Forum: Refrigerants and EPA regulations **NEW
  • Pro's Forum: Business & Marketing
  • Pro Forum: Residential Refrigeration and Appliances **NEW
  • Pro's Forum: Sales
  • Pro Forum: Equipment Recalls and Bulletins **NEW
  • Pro's Forum: Residential
  • Pro's Forum: Commercial
  • Pro's Forum: Geo Thermal / Water Source
  • Pro's Forum: Refrigeration & Ice
  • Pro's Forum: Chillers
  • Pro's Forum: Oil Burners
  • Pro's Forum: Hydronics/Boilers
  • Pro's Forum: Building Science Discussions
  • Pro's Forum: Training and Education
  • Pro's Forum: Instructors Forum NEW
  • Pro's Forum: Tips 'n Tricks of the Trade
  • Pro's Forum:The Gun Enthusiast
  • Frequently Asked Questions About Submissions
  • Manufacturers' Technical Information
  • Articles Authored by Others
  • Self-Authored Articles
  • Submit Quiz Questions
  • About the Suggestion Box
  • Voice Your Opinions
  • Share Ideas
  • Report Problems
  • Educational, Training & Reference Information
  • Manufacturer's Technical Information Links
  • Quiz Questions
  • Open Forum Discussion
  • Split Systems, Package Units, Furnaces
  • Geothermal / Water Source Heat Pumps
  • Specialty Systems
  • Boilers – Hydronic, Steam
  • Accessories – Humidifiers, Air Cleaners, HRUs, Fans, Filters, etc
  • Components – Coils, Heaters, Motors, etc.
  • Compressors
  • Oil Burners
  • Systems - General
  • Accessories – Pumps, Cooling Towers, Evap Condensers, etc
  • Components – Valves, Motors, Condensers, Evaporators, etc
  • Refrigeration Systems
  • Evaporators, Condensers, Etc.
  • Valves, Regulators, Filters, Etc.
  • Walk-Ins, Cold Storage
  • Food Service Equipment, Display Cases
  • Supermarket Cases & Compressor Systems
  • Ice Machines
  • Controls, Motors, Etc
  • HVAC Load Calc Software
  • Refrigeration Load Calc Software
  • HVACR Software & Online Training
  • HVACR Calculators & Apps
  • Formulas and Calculations
  • In Memoriam
  • Licensing, Laws, Codes and Certification
  • Jokes, Quotations, Humor, Wisdom Pills
  • Practice, Testing Area
  • Plumbing Forum Rules
  • Plumbing General Open Forum
  • Pro's Forum: Plumbing Discussion
  • Electrical Forum Rules
  • Open Discussion Electrical
  • Photovoltaic
  • New Products
  • Bonding & Grounding
  • Motors & Motor Controls
  • Test & Measurement
  • Tools & Equipment
  • Code Violations
  • Pro's Forum: Power Quality
  • Pro's Forum: Calculations & Electrical Theory
  • Pro's Forum: Electrical Business & Marketing
  • Pro's Forum: Estimating
  • Job Postings

vBulletin Message

The following errors occurred with your submission, quick reply, register now.

Please enter the name by which you would like to log-in and be known on this site.

  • Confirm Password:

Please enter a password for your user account. Note that passwords are case-sensitive.

  • Email Address:

Please enter a valid email address for yourself.

  • HVAC/R Contractor
  • HVAC/R Technician/Installer
  • HVAC/R Wholesaler/Distributor
  • HVAC/R Manufacturer
  • Manufacturer Rep
  • HVAC/R Consultant
  • HVAC/R Engineer
  • Facilities manager/Mechanical Engineer
  • Homeowner or Building/Equipment Owner (We welcome homeowners and Building owners. Help us customize your experience) Please post in the AOP Section
  • Residential HVAC
  • Light Commercial HVAC (up to 25 tons)
  • Commercial HVAC (over 25 tons)
  • Refrigeration
  • Hydronic Heating
  • Building Automation/Controls

Posting Permissions

  • You may post new threads
  • You may post replies
  • You may not post attachments
  • You may not edit your posts
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

  • HVAC-Talk.com

© VerticalScope Inc. All Rights Reserved.

  • Terms of Use & Privacy Policy
  • Testimonials
  • Search by Manufacturer
  • Aprilaire 2200 Space Guard Filter Media
  • Electrostatic Air Cleaner
  • Lennox type media filter rolls
  • Washable Furnace Filters
  • Air Conditioner Compressor Protection Delay Timer
  • 370VAC Dual Rated / Oval Motor Run Capacitors
  • 440VAC Dual Rated / Oval Motor Run Capacitors
  • Round Dual Rated Capacitors 370 Volts
  • Round Dual Rated Capacitors 440 Volts
  • Compressor Crankcase Heater
  • Condensate Overflow Switch
  • Condensate Pumps for Central Air Conditioning and Heat Pumps
  • Condenser Fan Motors for Carrier In the Round
  • Contactors for Air Conditioners and Heat Pumps
  • Contactors for Goodman Air Conditioners and Heat Pumps
  • Doolin's H.V.A.C. Troubleshooting Bible
  • DRV-102 Trane Variable Speed Compressor Drive
  • Ductwork Leaks
  • Evaporator Coil Cleaner
  • Fin Comb to Repair Condenser Coils
  • Freezestat for frozen air conditioning coils
  • Freon Leak Repair Kit. Stop Freon Leaks
  • Furnace - AC Repair Manuals
  • Air Conditioning Parts
  • Electric Furnace Heating and Air Conditioning Parts
  • Gas Furnace Parts
  • Heat Pump Parts
  • Goodman Condenser Fan Blades
  • Hard Start Kit for slightly stuck Air Conditioner Compressors
  • Hard Start Kit for stuck Air Conditioner Compressors
  • 0131M00429S Goodman 1/4 H.P. Cond Mtr S89-586
  • 0131M00008PS Goodman 1/3 H.P. Cond Mtr (S89-587)
  • 0131M00060S Goodman 1/6 H.P. Cond Mtr (S89-602)
  • 51-23052-11 Rheem-Ruud Cond Mtr
  • 51-23053-11 Rheem-Ruud Cond Mtr
  • 51-23055-11 Rheem-Ruud 1/5th H.P. Cond Mtr
  • 621911 Cond Fan Mtr for Miller Heat Pump
  • B13400251S Goodman 1/6 H.P. Cond Mtr (S89-588)
  • HC33GE233 Carrier H.P. cond fan motor
  • MOT04104 Trane-Am Std Condenser Fan Motor 1/5 HP
  • Leak Finder Solution
  • 10 MFD x 370 Volt Run Capacitor
  • 10 MFD x 440 Volt Run Capacitor
  • 12.5 MFD x 370 Volt Run Capacitor
  • 12.5 MFD x 440 Volt Run Capacitor
  • 15 MFD x 370 Volt Run Capacitor
  • 15 MFD x 440 Volt Run Capacitor
  • 17.5 MFD x 370 Volt Run Capacitor
  • 17.5 MFD x 440 Volt Run Capacitor
  • 2.0 MFD x 370 Volt Run Capacitor
  • 2.0 MFD x 440 Volt Run Capacitor
  • 2.5 MFD x 440 Volt Run Capacitor
  • 20 MFD x 370 Volt Run Capacitor
  • 20 MFD x 440 Volt Run Capacitor
  • 25 MFD x 370 Volt Run Capacitor
  • 25 MFD x 440 Volt Run Capacitor
  • 3.0 MFD x 370 Volt Run Capacitor
  • 3.0 MFD x 440 Volt Run Capacitor
  • 30 MFD x 370 Volt Run Capacitor
  • 30 MFD x 440 Volt Run Capacitor
  • 35 MFD x 370 Volt Run Capacitor
  • 35 MFD x 440 Volt Run Capacitor
  • 4.0 MFD x 370 Volt Run Capacitor
  • 4.0 MFD x 440 Volt Run Capacitor
  • 40 MFD x 370 Volt Run Capacitor
  • 40 MFD x 440 Volt Run Capacitor
  • 45 MFD x 370 Volt Run Capacitor
  • 45 MFD x 440 Volt Run Capacitor
  • 5.0 MFD x 370 Volt Run Capacitor
  • 5.0 MFD x 440 Volt Run Capacitor
  • 50 MFD x 370 Volt Run Capacitor
  • 50 MFD x 440 Volt Run Capacitor
  • 55 MFD x 370 Volt Run Capacitor
  • 55 MFD x 440 Volt Run Capacitor
  • 6.0 MFD x 370 Volt Run Capacitor
  • 6.0 MFD x 440 Volt Run Capacitor
  • 60 MFD x 370 Volt Round Run Capacitor
  • 60 MFD x 370 Volt Run Capacitor
  • 60 MFD x 440 Volt Run Capacitor
  • 7.5 MFD x 440 Volt Run Capacitor
  • 70 MFD x 370 Volt Run Capacitor
  • Amana A.H.-Elec Furnace Motors
  • Amana AC and Heat Pump Condenser Fan Motors
  • Amana Gas Fur and Pcgk Unit Indoor Blw Motors
  • Amana Gas Furnace Parts
  • Amana Heating and Air Conditioning Parts
  • Armstrong AC and Heat Pump Cond Fan Motors
  • Armstrong Air Handler and Electric Furnace Motors
  • Armstrong Gas Fur and Pcgk Indoor Blw Motors
  • Armstrong Heating and Air Conditioning Parts
  • Blower Motors
  • Capacitor Education
  • Carrier AC and Heat Pump Cond Fan Motors
  • Carrier Air Handler and Electric Furnace Motors
  • Carrier Gas Fur and Pckg Indoor Blower Motors
  • Carrier Gas Furnace Parts
  • Coleman AC and Heat Pump Cond Fan Motors
  • Coleman Air Handler and Electric Furnace Motors
  • Coleman Gas Fur and Package Indoor Blw Motors
  • Coleman Heating and Air Conditioning Parts
  • Consolidated Parts
  • Furnace and Air Handler Motor Capacitors
  • Furnace Motor Installation Photos
  • Furnace, Air Conditioning Motor Education
  • Goodman AC and Heat Pump Cond Fan Motors
  • Goodman Air Conditioning Parts
  • Goodman Air Handler and Electric Furnace Motors
  • Goodman Air Handler Motors
  • Goodman Electric Furnace Parts
  • Goodman Gas Fur and Package Indoor Blw Motors
  • Goodman Gas Furnace Parts
  • Goodman Heat Pump Parts
  • Goodman Parts
  • HC680004 Carrier-Bryant Furnace Motor
  • Hi Speed Furnace and Air Handler Motors
  • ICP AC and Heat Pump Condenser Fan Motors
  • ICP Air Conditioning Parts
  • ICP Air Handler and Electric Furnace Motors
  • ICP Gas Furnace and Package Unit Indoor Blower Motors
  • ICP Gas Furnace Parts
  • ICP Heat Pump Parts
  • Luxaire Parts
  • Magic Chef AC and Heat Pump Cond Fan Motors
  • Magic Chef Air Handler and Electric Furnace Motors
  • Magic Chef Gas Furnace and Package Unit Indoor Blower Motors
  • Magic Chef Heating and Air Conditioning Parts
  • Nordyne AC and Heat Pump Cond Fan Motors
  • Nordyne Air Handler and Electric Furnace Motors
  • Nordyne Gas Fur-Package Indoor Blw Motors
  • Nordyne Gas Furnace Parts
  • Nordyne Parts
  • O.E.M. Air Handler and Electric Furnace Motors
  • POC 7.5 7.5 MFD x 370 Oval Volt Run Capacitor
  • Rheem-Ruud AC and H.P. Cond Fan Motors
  • Rheem-Ruud Air Handler and Electric Furnace Motors
  • Rheem-Ruud Gas Fur and Pckg Ind Blower Motors
  • Rheem-Ruud OEM Furnace motors and capacitors
  • Rheem/Ruud Gas Furnace Parts
  • Rheem/Ruud Parts
  • S1- 02420043700 York 5 MFD x 370 Volt Oval Run Capacitor
  • S1- 02420045700 York 7.5 MFD x 370 Volt Oval Run Capacitor
  • S1-02420046700 York 10 MFD x 370 Volt Oval Run Capacitor
  • S1-02423211003 York 3/4 HP Furnace Blower Motor
  • S1-02423238001 York 1 HP Fur Mtr
  • S1-02425900000 York 15 MFD x 370 Volt Oval Run Capacitor
  • S1-02426087000 York 1/2 H.P. Air Handler Blower Motor S89-682
  • Trane AC and Heat Pump Condenser Fan Motors
  • Trane Air Handler and Electric Furnace Motors
  • Trane Gas Fur and Pcgk Indoor Blw Motors
  • Trane Gas Furnace Parts
  • Trane Replacement Heating and Air Conditioning Parts
  • York AC and Heat Pump Condenser Fan Motors
  • York Air Conditioning Parts
  • York Air Handler and Electric Furnace Motors
  • York Air Handlers and Electric Furnace Parts
  • York Gas Fur-Package Indoor Blw Motors
  • York Gas Furnace Parts
  • York Heat Pump Parts
  • York Heating and Air Conditioning Parts
  • Nu Blast Coil Cleaner
  • RBM 90-340 Switching Relay
  • Refrigerant Line Insulation
  • Service Valve Caps
  • Time Delay Cartridge Fuses
  • UV Lamps for Mold Control
  • Water Treatment for your Humidifier and Evaporator Coil Condensate Pan
  • Blower Wheels for Furnaces and Air Handlers
  • Torsion Flex Motor Mounts with Grommets
  • Universal Belly Band Motor Mounts with Grommets
  • Furnace Bearing Bracket and Bracket Kits
  • Furnace Motor Belt Adjustment - Tail Piece Assembly
  • Blower Shafts for Belt Driven Motors
  • Cartridge Type Blower Bearings
  • Oil Type Replacement Blower Bearings
  • Pitch Gauges and Fan Pullers
  • Pre Lubricated Heavy Duty Bearings for Heating and Air Conditioning
  • Self Aligning Blower Bearings
  • Stamped Bearing Brackets for Furnaces
  • Thrust Collars
  • Thrust Spacer Kit
  • 12W64 Armstrong 95% Control Board
  • 17W82 Concord Furnace Spark Ignition Control Module Kit
  • 56W19 Armstrong-Concord Ignition Control Board
  • 1128701A Amana Furnace Model EPCG3612-ID Ignition Control Board
  • 20224302 Amana Furnace Model GUIB/GCIB and GUID Control Board
  • PCBBF118S Amana Furnace Model GUIC115FA50 Control Board
  • PCBBF124S Amana Furnace Model GUVA090BX50 Control Board
  • 40403003 Armstrong 80% Furnace Control Board
  • 60M32 Armstrong Gas Package Unit Control Board
  • RA161 Armstrong Gas Package Unit Control Board Kit
  • 313680-751 Carrier,Bryant,Payne Inducer Control Board
  • 325879751 Bryant 2 stage Control Board
  • CESO11005702 Carrier, Bryant Control Board
  • ICM270, 271 and 275 Control Boards
  • R99G004 Bryant Furnace Control Board
  • 325878751 Carrier 80% Furnace Printed Circuit Board Kit
  • 695-101 Carrier 80% Furnace Printed Circuit Board (Fan Control)
  • Carrier Control Board HH84AA021 (ICM 275C)
  • Carrier, Bryant, Payne Control Board CESO 110074-01
  • HK61EA005 Carrier Air Handler Control Board
  • ICM282C Furnace Control Board
  • LH33WP003 Carrier Ignition Control Printed Circuit Board
  • LH33WZ510 Carrier-Bryant/Payne Spark Igniter Control
  • LH33WZ512A Carrier-Bryant/Payne Spark Igniter Control
  • 7681-317P Coleman Evcon Lower Control Board
  • 7681-318 Coleman Blend Air II Control Board
  • S1-43101972100 York Diamond 80 Control Board
  • 1014460 Comfortmaker Furnace Fan Timer
  • 1065188 Tempstar Furnace Fan Timer
  • 1085928 Comfortmaker Air Handler Fan Timer
  • 1170063 Furnace Fan Timer
  • 1395336 Heil Air Handler Time Delay Relay
  • 1395338 Comfortmaker Furnace Control Board
  • 34332100 Comfortmaker Defrost Board
  • HQ1084197HW Heil Control Board
  • Consolidated Furnace Fan Timer
  • B1809904 Goodman Timed Fan Control
  • B1809911 Goodman Timed Fan Control
  • B1809913S Goodman Furnace Control Board Kit
  • B1809923 Goodman Control Board
  • Goodman Control Board B18099-23 Instructions
  • PCBAG123S Goodman-Janitrol Direct Spark Ignition Control Board
  • PCBBF107S Goodman Control Board
  • PCBBF112S Goodman Control Board
  • PCBFM131S Goodman-Janitrol Air Handler Time Delay
  • PCBKF102S 2 Stage Goodman Control Module
  • Honeywell Universal Control Board ST9120U1011
  • Honeywell Control Board ST9101A1022
  • Honeywell Smart Valve Fan Timer Universal Control Board ST9120U1011 replaces obsolete numbers ST9120C2010, ST9120B1005
  • Honeywell Smart Valve Fan Timer Control Board ST9120G4038
  • ICM281 Furnace Control Board
  • Intertherm, Miller M1 Series furnace control board 903429
  • Nordyne Furnace Control Board 903106,624591-A,624591-B, 624591-D, JHL
  • Luxaire 2 stage control bd 331-09168-000
  • Many York Boards and others
  • S1-03101264002 Luxaire Air Handler Control Board
  • S1-33102956000 Luxaire Furnace Control Board for Models G8T and G9T
  • S1-03101290000 York Control Module
  • 4116000 Consolidated Industries Control Module
  • Fraser Johnson Heat Pump Air Handler Control
  • S1- 03101909000 York Furnace Control
  • S1-02532634000 York Control Board
  • S1-02535304000 York Spark Ignition Control
  • S1-03100652000 York Control Board
  • S1-03100862700 York Economizer Control Board
  • S1-03100880001 York Control Board
  • S1-03100880002 York Control Board
  • S1-03101146700 York Control Module
  • S1-03101212700 York Control Board
  • S1-03101955000 York CFM Selection Control Board
  • S1-03101958000 York CFM Selection Control Board
  • S1-33101993000 York Circuit Board Kit
  • S1-33109150002 York Control 2 Stage Heating; Cooling with Communication
  • Nordyne 624-625 Electric Furnace Control Board
  • 47-100436-02 Rheem-Ruud Time Delay Air Handler Blower Relay
  • 47-21776-86 Rheem-Ruud Defrost Board Kit
  • 47-22445-01 Rheem-Ruud RGEB/UGEB,RGDE/UGDE Circuit Board
  • 47-22481-01 Rheem-Ruud Circuit Board
  • 47-22827-83 Rheem-Ruud Standing Pilot Furnace Control Board
  • 47-23619-03 Rheem-Ruud Circuit Board
  • 62-100610-02 Rheem-Ruud (2) stage heat 90% furnace control board
  • 62-102635-81 Rheem-Ruud 80% (2) Stage Heat Control Board
  • 62-24084-82 Rheem-Ruud Furnace Control Board
  • 62-24140-04 Rheem-Ruud Furnace Control Board
  • 62-24268-03 Rheem-Ruud Furnace Control Board
  • 62-25341-81 Rheem-Ruud Furnace Ignition Control Board
  • 1005229 Tempstar Furnace Fan Timer
  • 1054636 Tempstar Furnace Fan Timer
  • 1084197 Tempstar Furnace Control Board
  • Thermal Zone Furnace Control Board 624591-A and B
  • CNT00917 Trane-G.E. Defrost Terminator Thermostat Sensor
  • CNT01538 Trane TWE Air Handler Control Board
  • KIT17858 Trane 2 Stage Control Board
  • CNT02236 Trane Defrost control
  • CNT02536 Trane-American Standard XV90 (2) stage-variable speed Gas Furnace Control
  • CNT02871 Trane-American Standard XL90 (2) Stage Furnace Control Board
  • CNT02941 Trane Defrost Control
  • CNT03457 Trane Control Board
  • CNT03484 Trane-American Standard Direct Spark Ignition Control Board
  • CNT03728 Trane Dual Compressor Control Board
  • CNT03776 Trane Control Board Kit
  • CNT07941 Trane Integrated Fan Control
  • CNT05001 Trane Defrost Control Board
  • CNT05165 Trane XE90 and 80% Single Stage Furnace Fan Control
  • CNT0915 G.E. De Ice Control
  • KIT06839 Adapter kit for use with CNT03457

KIT08282 Trane Voyager Package Unit Control Board

  • KIT15815 Trane XV80 (2) stage-variable speed Gas Furnace Control
  • KIT15943 Trane XL80 80% Gas Furnace Fan Control
  • RLY00892 Trane Defrost Relay
  • RLY01237 Trane Combustion blower board relay conversion
  • RLY02807 Trane Time Delay Air Handler Blower Relay
  • White Rodgers Universal 50A55-843 and 50A65-843 Furnace Control Boards
  • White Rodgers 50A55-843 Universal Ignition module
  • White Rodgers 50A65-843 Universal Integrated Fan Control
  • White Rodgers 50D50-842 Universal Direct Spark Ignition Control
  • White Rodgers 50D50-843 Universal Direct Spark Ignition Control
  • White Rodgers 50E47-843 Universal Control Board
  • S1-02525436700 York Stellar Control Board, 50E47-843
  • S1-02632588003 York Control Board
  • S1-03100254700 York Logic Module
  • S1-03101280000 York Package Unit Control Board
  • S1-33109139000 York Defrost Board Kit
  • York Defrost Board 031-01268-000, 031-01222-000
  • Belt Drive Furnace Motors
  • Electric Furnace Element Re String Kits
  • Electric Furnace Heat Sequencer
  • Goodman Blower Wheels
  • Goodman Furnace, Heat Pump and AC Transformers
  • MOT08399 Trane Air Handler Blower Motor 1/6 HP
  • Honeywell Transformer L38-636
  • Honeywell Transformer L40-744
  • Honeywell Transformer L40-745
  • SWT01280 Trane High Temp. Limit Switch
  • 0809/0I R.T.V. High Temperature Silicone Sealant
  • 1172197 ICP Pressure Switch
  • 51-23012-41 Trip Saver Motor 115 Volt
  • A136 Fasco Rheem-Ruud Inducer
  • 0131F00041S Goodman 1/3 HP Fur Mtr S83-504
  • 0231K00034A Amana 1 H.P. Variable Speed Furnace Motor
  • 1001480 1 H.P. ICP Furnace Blower Motor
  • 1009052 1/2 H.P. ICP Furnace Blower Motor
  • 1010263 3/4 H.P. ICP Furnace Blower Motor
  • 1011404 3/4 H.P. ICP Furnace Blower Motor
  • 1013341 1/2 H.P. ICP Furnace Blower Motor
  • 1014028 1/2 H.P. ICP Furnace Blower Motor
  • 10219707S Amana 3/4 H.P. Furnace Motor
  • 1054585 1 H.P. ICP Package Unit Blower Motor
  • 1054586 ICP 1 H.P. Package Unit Blower Motor
  • 20046612S Amana 3/4 H.P. Furnace Motor
  • 462432 Intertherm combustion blower motor assembly
  • 51-23014-32 Rheem-Ruud 1/4 HP Furnace Motor
  • 51-23102-04 Rheem-Ruud 1/2 HP Furnace Motor
  • 51-24070-02 Rheem-Ruud 1/2 HP Indoor Blower Motor
  • 51-24272-01 Rheem-Ruud 1/2 HP Furnace Motor
  • 51-25023-01 Rheem-Ruud 3/4 HP Furnace Indoor Blower Motor
  • 611798 1/3 H.P. ICP Furnace Blower Motor
  • 613209 3/4 H.P. ICP Furnace Blower Motor
  • B1340020S Goodman 1/2 H.P. Fur Mtr (S88-867)
  • B1340021S Goodman 1/3 H.P Fur Mtr S88-868
  • B1340022S Goodman Double Shaft Fur Mtr
  • B1340023S Goodman 3/4 HP Fur Mtr S88-869
  • Furnace and Air Handler Motor Brackets
  • Furnace Blower Repair Parts
  • Goodman Variable Speed Furnace Motors
  • MOT02609 Trane Air Handler Blower Motor 1/2 HP
  • MOT02611 Trane Air Handler Blower Motor 1/4 HP
  • MOT02615 Trane 1/4 HP Air Handler Blower Motor
  • MOT02619 Trane 1/2 HP Furnace Motor
  • MOT02635 Trane Air Handler Blower Motor 1/3 HP
  • MOT12871 G.E.-Trane Furnace Blower Motor
  • MOT02883 G.E.- Trane 1/3 HP Furnace Blower Motor
  • MOT03023 Trane Furnace Blower Motor 1/3 HP
  • MOT03096 G.E.- Trane 1/3 HP Furnace Blower Motor
  • MOT03480 G.E.-Trane 1/2 HP Furnace Blower Motor
  • MOT07613 Trane 1/3 HP Fur motor
  • MOT18948 Trane 1/3 H.P. Fur Motor
  • MOT11993 Trane 1/2 HP Furnace motor
  • MOT12810 Trane 3/4 HP Furnace Blower Motor
  • MOT12867 G.E.- Trane 1/5 HP Furnace Blower Motor
  • Heating and Air Conditioning Motor Run Capacitors
  • Nordyne 903433 motor for M1M (C) and M1M (D) furnaces
  • Nordyne One third HP furnace motor
  • O.E.M. Gas Furn-Package Unit Indoor Blower Motors
  • Amana Circuit Boards
  • Armstrong Circuit Boards
  • Bryant Circuit Boards
  • Carrier, Bryant, Payne, Day and Night Circuit Boards
  • Coleman Evcon Control Boards
  • Comfortmaker Circuit Boards
  • Goodman/Janitrol/GMC Circuit Boards
  • Heil Heating and Air Conditioning Circuit Boards
  • Honeywell Furnace Circuit Boards
  • Intertherm Circuit Boards
  • Luxaire Circuit Boards
  • Nordyne Circuit Boards
  • Rheem/Ruud Circuit Boards
  • Snyder General Circuit Boards
  • Tempstar Circuit Boards
  • Trane Circuit Boards
  • White Rodgers Circuit Boards
  • York Circuit Boards
  • Fan center for older furnaces
  • A196 Fasco replacement Trane Inducer
  • 0271F00126S Amana Draft Inducer
  • 1006168 ICP Furnace Draft Inducer
  • 1011350 Comfortmaker 90% Furnace Inducer
  • 1011350 Heil 90% Furnace Inducer
  • 1011412 Tempstar Furnace Draft Inducer
  • 1011899 Tempstar Furnace Draft Inducer
  • 1013833 Comfortmaker Furnace Inducer
  • 1013833 Tempstar Furnace Draft Inducer
  • 1054268 Tempstar Furnace Draft Inducer
  • 1172824 ICP Furnace Draft Inducer
  • 20044403 Amana Inducer for GUID090DA30
  • 309868755 Carrier-Bryant Furnace Draft Inducer Kit
  • 48GS-060115301 Carrier Model Inducer
  • 51-21964-11 Rheem-Ruud Draft Inducer Kit
  • 70-100612-01 Rheem-Ruud Furnace Draft Inducer
  • 70-101087-81 Rheem-Ruud Furnace Draft Inducer
  • 70-21496-83 Rheem-Ruud Furnace Draft Inducer
  • 70-22436-01 Rheem-Ruud Furnace Draft Inducer
  • 70-24033-01 Rheem-Ruud Furnace Draft Inducer
  • 70-24157-03 Rheem-Ruud Furnace Draft Inducer
  • 70-24206-01 Rheem-Ruud Furnace Draft Inducer
  • 70-24206-02 Rheem-Ruud Furnace Draft Inducer
  • 70-42241-01 Rheem-Ruud RRGF/URGF Package Unit Draft Inducer
  • 70-42278-02 Rheem-Ruud Furnace Draft Inducer
  • 703001 Rheem-Ruud Furnace Draft Inducer
  • A063 Fasco replacement Inducer for York S1-02622239700
  • A179 Fasco replacement Inducer for ICP 1006168
  • A079 Fasco Inducer for Rheem-Ruud and Goodman
  • A081 Magic Chef Inducer Motors
  • A083 Fasco York Furnace Draft Inducer
  • A088 Coleman Furnace Draft Inducer
  • A090 Fasco Rheem-Ruud Draft Inducer
  • A129 Amana Draft Inducer
  • A137 Fasco York Furnace Draft Inducer S1-02425057000
  • A143 Fasco BLW0473 Trane XE 80 Draft Inducer
  • A144 Fasco York Furnace Draft Inducer S1-32625999000
  • A146 Fasco BLW00362 Trane and American Standard 80% Furnace 2 Stage Draft Inducer
  • A146 Fasco BLW00836 Trane and American Standard 80% Furnace (2) Stage Draft Inducer
  • A155 Fasco Armstrong Draft Inducer
  • A170 Intercity Furnace Draft Inducer
  • A172 Fasco Intercity Furnace Draft Inducer
  • A192 Fasco Trane Furnace Model BLU Inducer
  • A194Fasco BLW01321 Trane and American Standard 80% Furnace 2 Stage Draft Inducer
  • A195 Fasco BLW00864 Trane and American Standard 90% Furnace Inducer
  • A241 Fasco Rheem-Ruud Draft Inducer
  • A367 Fasco BLW01322 Trane XL80 and American Standard Furnace Draft Inducer
  • Armstrong Inducer Motors
  • B1859001S Goodman GUN-B and GUS Series Furnace Draft Inducer
  • B1859005 Goodman GMP 80% Furnace Draft Inducer
  • B2833001 Goodman GMPN 90% Furnace Draft Inducer
  • BLW01137 Trane Furnace Draft Inducer
  • BLW0569 Trane Package Unit Furnace Draft Inducer
  • Carrier Furnace Draft Inducer Kit
  • Comfortmaker Furnace Inducer 1006168
  • Goodman GMT Furnace Draft Inducers
  • Goodman Inducer Motors
  • 4053501S Goodman/Janitrol/GMC Draft Inducer Chimney
  • Heil DC90 Furnace Inducer 1164280, 1011409
  • Heil Furnace Draft Inducer 1006168
  • Inter City 90% Furnace Inducer
  • Magic Chef Furnace Draft Inducer Kit 06428D455 for many 80% furnaces
  • Nordyne, Miller Furnace Draft Inducer
  • Nordyne Inducer
  • R0156859 Amana Draft Inducer
  • R06428D455 Armstrong Furnace Draft Inducer Kit
  • Rheem/Ruud RGEA/UGEA Upflow 90% Condensing Furnace Inducer
  • S1-02632588049 Consolidated Furnace Inducer
  • S1-02633999001 York Furnace Draft Inducer
  • S1-32632067000 York Furnace Draft Inducer
  • S1-37310337702 York P2MP014N08001C Furnace Draft Inducer
  • Tempstar 90% Furnace Inducer
  • Variable Speed 92% Furnace Draft Inducer for Trane and American Standard
  • Goodman Flame Sensors
  • SEN01114 Trane Flame Sensor
  • SEN00355 Trane Flame Sensor
  • Furnace Vibration Absorbers
  • Furnace Fan Limit Control
  • Goodman Gas Furnace Limit Switches
  • Goodman Gas Furnace Roll Out Switches
  • Plenum Thermostats
  • SWT01263 Trane High Temp. Limit Switch
  • SWT01635 Trane High Temp Limit Switch
  • SWT01652 Trane Furnace limit switch
  • SWT01729 Trane High Temperature Plenum Thermostat
  • 41-401 Hot Surface Igniter
  • 41-402 Hot Surface Igniter
  • 41-403 Hot Surface Igniter
  • 41-404 Hot Surface Igniter
  • 41-405 Hot Surface Ignitor
  • 41-406 Hot Surface Ignitor
  • 41-407 Hot Surface Igniter
  • 41-408 Hot Surface Ignitor
  • 41-409 Hot Surface Igniter
  • 41-410 Hot Surface Igniter
  • 41-411 Hot Surface Ignitor
  • 41-412 Hot Surface Igniter
  • 41-414 Hot Surface Igniter
  • Hot Surface Furnace Igniter Education
  • Hot Surface Igniter Cross Reference
  • IGN00054 Trane Hot Surface Igniter
  • IGN00145 Trane Silicone Nitride Hot Surface Igniter
  • L40-530 Goodman Mini Hot Surface Igniter
  • Nordyne Spiral Hot Surface Igniter
  • Smart Valve 24 Volt Hot Surface Igniter
  • 780-783 Robertshaw Rheem-Ruud Hot Surface Ignition Control
  • 780-785 Robertshaw Hot Surface Ignition Control
  • 780-790 Robertshaw Rheem Water Heater HSI Control
  • Fenwal Direct Spark Ign Control
  • Honeywell S87B1065 Direct Spark Ignition Control
  • Honeywell S87D1004 Direct Spark Ignition Control
  • Johnson G776RGD-14 Lennox Ignition Control
  • Robertshaw Universal 780-910 HSI Ignition Control
  • S1-1474-0061/A Robertshaw Evcon Ignition Control
  • Millivolt Powerpile Generator
  • 319338401 Carrier-Bryant Pressure Switch Kit
  • 42-101233-81 Rheem-Ruud Pressure switch
  • 42-24166-89 Rheem-Ruud Pressure switch
  • 42-24194-82 Rheem-Ruud Pressure switch
  • Goodman Gas Furnace Pressure Switches
  • S1-37320717001 York Furnace Draft Inducer
  • Sidewall Flue Vent Kit for 90% Furnaces
  • Standing Pilot Thermocouples
  • SWT01611 Trane High Temperature Limit Switch
  • SWT02513 Trane Pressure Switch
  • SWT1273 Trane High Temp. Limit Switch
  • SWT1373 Trane Pressure Switch
  • SWT2293 Trane Pressure Switch
  • SWT04232 Trane Dual Pressure Switch
  • SWT2522 Trane Pressure Switch
  • SWT2523 Trane Pressure Switch
  • SWT2528 Trane Pressure Switch
  • Economy Digital Heat Pump Programmable Thermostat
  • Economy Digital Thermostat
  • Heating Only Vertical Mechanical Thermostat
  • Horizontal Mechanical Heat Only Thermostat
  • Introducing the Total Line Wireless Thermostat!
  • Lowest Cost Horizontal Mechanical Thermostat
  • Mid Range Digital, Programmable Thermostat
  • Mid Range Heat Pump Programmable Thermostat
  • Millivolt Thermostat Heating Only with positive off feature
  • Totaline Flush Mount Thermostat
  • Introducing the Venstar Wireless Thermostat!
  • Vertical Mechanical Heat/Cool Thermostat
  • 621911 Nordyne Heat Pump Condenser Fan Motor
  • 46K67 Armstrong Heat Pump Defrost Control
  • Heat Pump Defrost Termination Thermostat
  • ICM302C Nordyne Defrost Board
  • ICM303C Defrost Board
  • ICM304C Defrost Board
  • ICM315C Defrost Board
  • ICM316C Defrost Board
  • ICM318C Defrost Board
  • ICM319C Defrost Board
  • ICM320C Defrost Board
  • ICM321C Defrost Board
  • ICM322C Defrost Board
  • ICP HQ108671RC, 1088977, 1087953 Defrost Board
  • Nordyne 917178 Defrost Control Board
  • PCBDM101S Goodman Defrost Board
  • Rheem-Ruud Defrost Board 47-102684-83
  • S1-03101954000 York Defrost Control
  • York Heat Pump Defrost Board 031-01257-000
  • ICM300 Heat Pump Defrost Timers
  • MOT03125 Trane Condenser Fan Motor 1/4 HP
  • Aprilaire 4005 Solenoid
  • Aprilaire 400A Humidifier
  • Aprilaire 4040 Solenoid
  • Aprilaire 600A and M Humidifier
  • Aprilaire 700A Humidifier
  • Full Humidifier Education
  • Saddle Valve for self tapping water access
  • Water Panel 10
  • Water Panel 12
  • Water Panel 35
  • 3585 G.E. 1/3 HP Furnace Motor S88-736
  • Evaporative Cooler Distributor Repair Kits
  • Evaporative Cooler Fresh Air Cake
  • Evaporative Cooler Pads and Rolls
  • Evaporative Cooler Pumps
  • Evaporative Cooler Water Baskets
  • Evaporative Cooler Water Float Valve
  • Evaporative Cooler Water Treatment

PLEASE NOTE: U.P.S. DOES NOT OPERATE ON THE WEEKEND, SO IF YOU ORDER A NEXT DAY AIR PART ON FRIDAY, YOU WILL NOT GET IT ON THE WEEKEND! WE CAN'T BE RESPONSIBLE FOR THE U.P.S. DELIVERY SCHEDULES. IF YOU NEED A PART FOR THE WEEKEND, PLEASE ORDER BY THURSDAY BEFORE NOON MOUNTAIN TIME.

IMPORTANT: Due to the nature of the products we sell directly to homeowners we must have you read and understand our terms of use page. If for any reason you can't understand or agree to these terms we suggest you call a reputable Heating and Air Conditioning Contractor in your area for assistance. Your safety and the manufacturers warranty also requires it. Please click this link.

Terms of Use and Privacy Policy

Copyright © 2011 MyHVACParts.com. All rights reserved.

Defence Forum & Military Photos - DefenceTalk

  • New comments
  • Military Photos
  • Russian Military
  • Anti-Aircraft
  • SA-21/S-400 Triumf

92N6E Radar, S-400

92N6E Radar, S-400

  • Oct 18, 2010

Media information

Share this media.

  • This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. By continuing to use this site, you are consenting to our use of cookies. Accept Learn more…

Fontesk

Moscow Metro Font

moscow_metro-6

Moscow Metro is a multi-line display typeface inspired by the Moscow underground map. It comes in Regular and Color versions.

Moscow Metro is ideal for posters and headlines, neon signage and other artworks.

  • Share by email

Designed by: Nadira Filatova Website

License: free for commercial use.

sudo

IMAGES

  1. Trane Ignition Control Circuit Board CNT07738

    trane voyager ignition board

  2. Trane Ignition Control Board CNT03457

    trane voyager ignition board

  3. KIT15815 Trane ignitor and control board kit

    trane voyager ignition board

  4. Trane OEM Ignition Control Replacement Module KIT08282

    trane voyager ignition board

  5. KIT15816 Trane American Standard ignitor, control board and wiring kit

    trane voyager ignition board

  6. Trane MOD01298 Ignition Control Board

    trane voyager ignition board

VIDEO

  1. Lennox RTU Faulty Ignition Board

  2. Carrier RTU Faulty Ignition Board

  3. Commercial Trane RTU

  4. 1 & 2 Voyager Ignition

  5. what will happened if you take a hover board in the trane in Fortnite

  6. Trane Furnace control board replacement ICM 2812 Kit

COMMENTS

  1. PDF Installation, Operation, and Maintenance Voyager Commercial

    Voyager ™ Commercial ... YC*275B, 305B, 350B, 400B, 500B ©2021 Trane RT-SVX34U-EN Introduction Read this manual thoroughly before operating or servicing this unit. Warnings, Cautions, and Notices Safety advisories appear throughout this manual as required. Your personal safety and the proper

  2. PDF Installation, Operation, and Maintenance Voyager™ 3

    4. Remove the dust cap from the tubing connector located below the sensor in the vertical support. 5. Attach one end of the 50' x 3/16" O.D. factory provided pneumatic tubing to the sensor's top port, and the other end of the tubing to the connector in the vertical support. Discard any excess tubing.

  3. Ignition board replacement on a trane voyager roof top unit

    Description www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lighthttps://amzn.to/3pe2hYHMilwaukee M12 Surge Hydraulic Driver Ki...

  4. Trane Voyager Commercial Installation & Operation Manual

    Air Conditioner Trane Voyager CV Installation And Maintenance Manual. 27.5 to 50 ton 60 hz 22.9 to 41.7 ton 50 hz cv, vav, or sz vav rooftop air conditioners with reliatel controls, r-410a refrigerant (122 pages) Air Conditioner Trane Voyager TC* User Manual. Packaged cooling & gas/electric rooftops 12 1/2-25 tons — 60 hz (109 pages) Air ...

  5. PDF Packaged Rooftop Air Conditioners Voyager™ Commercial with ReliaTel

    Packaged Rooftop Air Conditioners Voyager™Commercial with ReliaTel™Controls. Including eStage™ 27.5 to 50 Tons - 60 Hz 22.9 to 41.7 Tons (81-148 kW) - 50 Hz. ©2021 TraneRT-PRC033N-EN. Introduction. Packaged Rooftop Air Conditioners. Through the years, Trane has designed and developed the most complete line of Packaged Rooftop products ...

  6. TRANE VOYAGER COMMERCIAL INSTALLATION, OPERATION AND ...

    Air Conditioner Trane Voyager WS 150-24 Installation, Operation And Maintenance Manual. Packaged rooftop air conditioners - heat pump 121/2 - 20 ton, 60/50 hz (44 pages) Air Conditioner Trane Voyager RT-DS-10 Manual. Packaged rooftop air conditioners 23 to 42 ton (81-148 kw) commercial 50 hz (44 pages) Air Conditioner Trane Voyager TS 150 ...

  7. What are the gas heat fault codes for Reliatel controlled ...

    Wiring issue or problem with ignition module or RTRM. 2 Flash. System lockout - failure to sense flame. Failure to ignite, no spark, low/no gas pressure. 4 Flash. TCO (high temperature limit) circuit open. excessive heat in the combustion chamber, low airflow, 5 Flash. Flame being sensed, but gas valve not energized.

  8. Trane Voyager ignition control module

    Trane Voyager ignition control module. md# YCD150D4LBBB. ICM board #X13650882-01. Anyone have any detailed troubleshooting info. on this control? IO&M doesn't say much about it.

  9. List of Light Commercial LED Codes

    List of Light Commercial LED Codes. LED Blink Codes. Electromechanical Ignition Board. 2 flash - 1 Hour Lockout. 3 flash - Pressure Switch. 4 flash - TCO Open. 5 flash - Flame W/O Gas. 6 flash - Rollout Switch Open. 7 flash - W1 / W2 Swapped.

  10. KIT08282 Trane Voyager Package Unit Control Board

    KIT08282 Trane Voyager Package Unit Control Board (KIT08282) If you have a bad control board in a Trane Voyager Package unit, this is the kit you need. It contains the new board to be used with the (9) pin edge connector, a new mounting plate, a wiring harness and wire ties with full instructions direct from Trane. $229.95.

  11. Machine-Building Plant (Elemash)

    In 1954, Elemash began to produce fuel assemblies, including for the first nuclear power plant in the world, located in Obninsk. In 1959, the facility produced the fuel for the Soviet Union's first icebreaker. Its fuel assembly production became serial in 1965 and automated in 1982. 1. Today, Elemash is one of the largest TVEL nuclear fuel ...

  12. TRANE TEKNIK, AO Company Profile

    Find company research, competitor information, contact details & financial data for TRANE TEKNIK, AO of Elektrostal, Moscow region. Get the latest business insights from Dun & Bradstreet.

  13. 92N6E Radar, S-400

    First S-400 bltn, Elektrostal, Moscow.

  14. Moscow Metro Font › Fontesk

    License: Free for commercial use. July 14, 2020 featured in Display. Download Moscow Metro font, a multi-line display typeface in two styles, inspired by the Moscow underground map. Moscow Metro is ideal for posters and headlines, neon signage and other artworks.