- Skip to main content
- Skip to main navigation
- Skip to footer
SIMARIS curves
As an already registered user simply enter your userame and password in the login page in the appropriate fields. After logging in you will see your user specific settings and prices as well as having other functions at your disposal. If you have forgotten your password please use link "Forgotten Password?" on the login page.
- Drive technology
- Automation technology
- Building Technologies
- Low-Voltage controls and distribution
- Market-specific solutions
- ... and everything else you need
- Ordering Data Overview
- Catalogs and Price Lists
- 1, css: {ActiveDot: $index() == $parent.displayedPage(), deactiveDot: $index() != $parent.displayedPage() }'>
- 1" class="internalLink showAllAccessories">Show all
- © Siemens 2022
- Corporate Information
- Terms of Use
- Data Privacy
- Cookie Policy
- Industry Mall T&C
IMAGES
VIDEO
COMMENTS
3VA5212-5EC31-0AA0. circuit breaker 3VA5 UL frame 250 breaking capacity class M 35kA @ 480 V 3-pole, line protection TM230, FTAM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=5...10 x In without. connection.
Time Current Characteristic Curve Auslösekennlinie Thermal Magnetic Trip Unit - TM210/230/240 with Ll Protection For coordination purposes only. Based on 400 C ambient, cold start. Connected with 4 feet of rated wire (750C) per terminal. Tested in open air with current in all main poles. 3VA5 Breaker, 3- or 4 poles Maximum Trip Unit Type Rating In
Tripping Curve 3VA with TM230/240 L1V 300 40 333 373 A DS 02 14.09.2020 3VA5340-. [E,G][C,F][3,4] Ir: Ii: TM230/240 ... Min. tripping time Time Current Characteristic Curve Auslösekennlinie Thermal Magnetic Trip Unit - TM230/240 with Ll Protection For coordination purposes only. Based on 400 C ambient, cold start. Connected with 4 feet of ...
trip brea kers Pa ne lb oa rd brea kers. 5. Therma etic trip brea kers Ge ne ra l purp ose brea kers (C IC O) 6. Electr on ic. trip brea kers. Adva nc e purpose brea kers. n . Breaki ng capacity @ 48 0 V AC: 3V A5 3V. 0. 200k A . 1. 10 0k A 10 0k. 4. 25 − . 5. 35kA 35kA. 6. 65kA. 10 0k 100kA . 8. − 15 0k. A. 100% A. Withou t Withou t. 3V A5 ...
Tripping Curve Overload 3VA5 with TM210/TM230 (for the North American Market) Display; Download (389 KB) DetailPages.ToPageTop. Also available in the following languages: ... Note: Depending on the effort involved, support may be subject to a charge. In this case, please have a Siemens Industry Service Card ready. You want to create CAx data ...
Trip unit 3VA5: characteristic MCS110 curve, type L I N BB - fix without BB Line protection TM210 fix without ED TM230 fix adj without EC TM240 adj adj without EF TM210 fix fix 100% GD TM230 fix adj 100% GC TM240 adj adj 100% GF Starter protection TM120M - adj without MH TM120M - adj without MU Trip unit 3VA6: 1) characteristic curve, type
3VA molded case circuit breakers offer safe and efficient application options for low-voltage power distribution. For the UL market the 3VA can be applied at a maximum of 600VAC and 1000VDC for industrial applications, infrastructure, or buildings. 3VA5 (thermal-magnetic trip unit) and 3VA6 (electronic trip unit) cover sizes 125A to 2000A for ...
Time Current Characteristic Curve Auslösekennlinie Thermal Magnetic Trip Unit - TM230 with Ll Protection For coordination purposes only. Based on 400 C ambient, cold start. Connected with 4 feet of rated wire (750C) per terminal. Tested in open air with current in all main poles. 3VA5 Breaker, 3 poles Maximum Trip Unit Type Rating In
Thermal-magnetic trip breakers Panelboard breakers Thermal-magnetic trip breakers General purpose breakers (CICO) Electronic trip breakers Advanced purpose breakers 4 5 6 In terrup ing C ap c y @ 480 V 3VA5 6 0 MCP/MCS 1 MCP/MCS MCP/MCS 2 250 A 3 400 A 4 25 kA 5 35 kA 6 65 kA 7 100 kA 8 150 kA Protection Functions: 3VA5 L I N* 3VA6 L S I G N ...
Tripping Curve 3VA with TM230/240 L1V 300 40 333 374 A DS 02 14.09.2020 3VA5445-. [E,G][C,F][3,4] Ir: Ii: TM230/240 ... Min. tripping time Time Current Characteristic Curve Auslösekennlinie Thermal Magnetic Trip Unit - TM230/240 with Ll Protection For coordination purposes only. Based on 400 C ambient, cold start. Connected with 4 feet of ...
Tripping Curve 3VA with TM230 L1V 300 40 332 377 A DS 01 02.12.2019 3VA5560-. [E,G]C[3,4] Ir/In: Ii/In: TM230 t/s ... +1000/0 Time Current Characteristic Curve Auslösekennlinie Thermal Magnetic Trip Unit - TM230 with Ll Protection For application and coordination purposes only. Based on 400 C ambient, cold start. Tested in open air with ...
Tripping Curve 3VA with TM230 L1V 300 40 333 378 A DS 01 04.12.2019 3VA5570- . [E,G]C[3,4] Ir: Ii: TM230 pdf 378aUD_01 700A 4200A 3500A 4900A 6300A ... Thermal Magnetic Trip Unit - TM230 with Ll Protection For coordination purposes only. Based on 400 C ambient, cold start. Connected with 4 feet of rated wire (750C) per terminal. Tested in open ...
Data sheet 3VA5580-5EC36-0AA0 circuit breaker 3VA5 UL frame 800 breaking capacity class M 35kA @ 480 V 3-pole, line protection TM230, FTAM, In=800A overload protection
3VA5110-6EF31-0AA0. circuit breaker 3VA5 UL frame 125 breaking capacity class H 65kA @ 480V 3-pole, line protection TM240, ATAM, In=100A overload protection Ir=80A...100A short-circuit protection Ii=5...10 x In without. connection.
Further Product Information. Product. Article Number (Market Facing Number) 3VA52226EC310AA0. Product Description. SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA52 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 225A 3-POLE (25KAIC AT 600V) (65KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii.
Siemens
Product. Article Number (Market Facing Number) 3VA51904EC310AA0. Product Description. SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA51 FRAME WITH STANDARD (CLASS S) BREAKING CAPACITY. 90A 3-POLE (14KAIC AT 600Y/347) (25KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii.
Time Current Characteristic Curve Auslösekennlinie Thermal Magnetic Trip Unit - TM210/230/240 with Ll Protection For coordination purposes only. Based on 400 C ambient, cold start. Connected with 4 feet of rated wire ... TM230/240: l. adjustable I - Rated Amps +300/0 TM210/230: I fixed at TM240: I adjustable .
The SIMARIS curves software, which also comes free of charge, visualizes characteristic curves with tolerance bands as well as setting options of specific parameters for low-voltage protective devices and fuses (IEC). Characteristic cut-off current and let-through energy curves are also displayed. Practical advantage: You can save selected ...
3VA5220-5EC31-0AA0. CIRCUIT BREAKER 3VA5 UL FRAME 250 BREAKING CAPACITY CLASS M 35KA @ 480V 3-POLE, LINE PROTECTION TM230, FTAM, IN=200A OVERLOAD PROTECTION IR=200A FIXED. SHORT CIRCUIT PROTECTION II=5...10 X IN W/O CONNECTION.
Product. Article Number (Market Facing Number) 3VA5580-5EC32-0AA0. Product Description. circuit breaker 3VA5 UL Frame 800 breaking capacity class M 35 kA @ 480 V 3-pole, line protection TM230, FTAM, In=800 A overload protection Ir=800 A permanently set short-circuit protection Ii=5...10 x In nut keeper kit. Product family.
3VA5340-5EC31-0AA0. CIRCUIT BREAKER 3VA5 UL Frame 400 BREAKING CAPACITY CLASS M 35kA @ 480 V 3POLE, LINE PROTECTION TM230, FTAM, In=400A WITHOUT OVERLOAD PROTECTION IR=400A FIXED SHORT CIRCUIT PROTECTION Ii=5...10 x In W/O CONNECTION. Model.
3VA1132-6EF36-0CA0. Product Description. circuit breaker 3VA1 IEC Frame 160 breaking capacity class H Icu=70 kA @ 415 V 3-pole, line protection TM240, ATAM, In=32 A overload protection Ir=22 A...32 A short-circuit protection Ii=5...10 x In terminal connection undervoltage release (UVR) 120-127 V AC 50/60 Hz. Product family.